Model | HML-0102 |
---|
Reliable tools that withstand extreme working conditions: engine vibration, humidity and aggressive media such as seawater. Especially designed for remotely measuring temperatures in chemical, petroleum and food industries.
Application: Chemical Industry, Oil industry, Food, HVAC and Cooling
STANDARD PARAMETERS
Mounting: See attached diagrams C
Closing: Bayonet. Sealed by rubber gasket
IP protection: IP65
Accuracy: Class 1.6
Temperature limits:
Room temperature: -40+60°C
Fluid overtemperature: maximum 10% end of scale
Max. pressure on stem: 25 bar
Temperature range: 0+120; 0+200; 0+400; -50+650°C/°F
Sensor element: Bourdon tube (Inert gas expansion). Room temperature compensator by bimetallic strip
Capillary length (L): 3; 5; 8 m
Stem length: 150; 250mm
Process connection: Plain Bulb, Sliding on the stem or crazy nut
Threaded connection: ½” BSP/ NPT, ⅜” BSP/NPT, ¾” BSP/NPT, M20x150 or M22x150
Antivibration liquid: Glycerin or dry
Vibration damping system: Upper plug
MATERIALS
Case and ring: AISI 304 Stainless steel
Moving parts and bourdon tube: Copper alloy
Threaded connection: AISI 304 Stainless steel
Display: Glass
Dial: White lacquered aluminum
Pointer: Black lacquered aluminum
Capillary coating: AISI 304 Stainless steel
Bulb/Stem: AISI 304 Stainless steel
Threaded connection: AISI 304 Stainless steel or Brass